Troubleshooting
WARNING:
To reduce the risk of fire, electric shock or
injury, unplug from the outlet before servicing.
Reduced Spray OR No Spray
Possible causes Remedies
1. Bladder may be empty 1. Turn power switch OFF; Refill bladder
with clean hot tap water.
2. 2-in-1 tank may not be seated properly. 2. Turn power switch OFF; remove tank
and reseat tanks.
3. Pump may have lost prime. 3. Turn power switch OFF; after 1 minute
turn ON and depress spray release trigger.
4. The pump belt may be broken. 4. Turn power switch OFF and unplug from the outlet. To
check if a pump belt has broken, you will need a flat
head screwdriver.
A. Insert the blade end into the slot of the belt access
door to release. Examine the belt for breakage. You
should be able to see the pump belt looped around the
motor shaft. If it is broken or missing, please refer to
Replacement Parts on page 14. A replacement belt may
be ordered by calling BISSELL Consumer Services
Complete installation instructions will accompany the
replacement belt.
B. When replacing belt access door be sure to line up
slots of belt access door with slots in machine,
slide door into place and snap shut.
DirtLifter PowerBrush Does Not Turn
Possible causes Remedies
1. The brush belt or pump belt is off or broken. 1. Refer to Remedy 4 above to check if brush
belt or pump belt is broken.
Cleaner Not Picking Up Solution
Possible cause Remedies
1. ReadyTools dial may be on the wrong setting 1. Set ReadyTools dial to either FLOOR CLEANING or
TOOLS.for the cleaning job.
2. Poor tool position. (Hand held attachments only). 2. Adjust angle; apply more downward pressure.
3. Removable nozzle may not be properly attached. 3. Make sure nozzle is on correctly by slightly raising
front of machine to line up slots on the base of
the machine with the hooks on nozzle. Attach at
base first and then click nozzle into place. Refer to
image 5 on page 9.
4. 2-in-1 tank lid is not properly installed. 4. Re-install lid; refer to the image on page 8.
5. 2-in-1 tank is not properly seated. 5. 2-in-1 tank must be firmly seated to function;
remove and reseat 2-in-1 tank.
6. 2-in-1 tank has picked up maximum dirty water. 6. Empty 2-in-1 tank and refill, refer to the
Operation section.
7. The lint screen may be clogged 7. Clean out lint screen. Refer to page 9.
Other maintenance or service not included in the manual should be
performed by an authorized service representative.
Thank you for selecting a BISSELL product.
Please do not return this product to the store.
Slots
B.
Pump Belt
A.
Page view 12